Safety information  
CAUTION  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN  
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR  
BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED  
SERVICE PERSONNEL.  
This symbol indicates that dangerous voltage consisting a risk of  
electric shock is present within this unit.  
This exclamation point symbol is intended to alert the user to  
the presence of important operating and maintenance (servicing)  
instructions in the literature accompanying the appliance.  
WARNING  
To reduce the risk of fire or electric shock, do not expose this appliance to rain  
or moisture.  
WARNING  
1. Be sure to use only the standard adapter that is specified in the specification sheet.  
Using any other adapter could cause fire, electrical shock, or damage to the product.  
2. Incorrectly connecting the power supply or replacing battery may cause  
explosion, fire, electric shock, or damage to the product.  
3. Do not connect multiple controllers to a single adapter. Exceeding the capacity  
may cause abnormal heat generation or fire.  
4. Securely plug the power cord into the power receptacle. Insecure connection  
may cause fire.  
5. When installing the controller, fasten it securely and firmly. The fall of controller  
may cause personal injury.  
6. Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or  
containers filled with water on top of the controller. Doing so may cause personal  
injury due to fire, electric shock, or falling objects.  
7. Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fire  
or electric shock.  
8. If any unusual smells or smoke come from the unit, stop using the product. In  
such case, immediately disconnect the power source and contact the service  
center. Continued use in such a condition may cause fire or electric shock.  
9. If this product fails to operate normally, contact the nearest service center. Never  
disassemble or modify this product in any way. (SAMSUNG is not liable for  
problems caused by unauthorized modifications or attempted repair.)  
10. When cleaning, do not spray water directly onto parts of the product. Doing so  
may cause fire or electric shock.  
English 3  
 
Safety information  
CAUTION  
1
2
3
4
5
6
7
1. Do not drop objects on the product or apply strong blows to it. Keep away from a  
location subject to excessive vibration or magnetic interference.  
2. Do not install in a location subject to high temperature (over 50°C), low  
temperature (below -10°C), or high humidity. Doing so may cause fire or electric  
shock.  
3. If you want to relocate the already installed product, be sure to turn off the power  
and then move or reinstall it.  
4. Remove the power plug from the outlet when there is a lighting storm. Neglecting  
to do so may cause fire or damage to the product.  
8
9
5. Keep out of direct sunlight and heat radiation sources. It may cause fire.  
6. Install it in a place with good ventilation.  
7. Avoid aiming the controller directly towards extremely bright objects such as sun.  
8. Apparatus shall not be exposed to dripping or splashing and no objects filled with  
liquids, such as vases, shall be placed on the apparatus.  
9. The Mains plug is used as a disconnect device and shall stay readily operable at  
any time.  
1
1
1
1
Correct Disposal of This Product (Waste Electrical & Electronic Equipment)  
(Applicable in the European Union and other European countries with separate collection systems)  
This marking on the product, accessories or literature indicates that the product and its electronic  
accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste  
at the end of their working life. To prevent possible harm to the environment or human health from  
uncontrolled waste disposal, please separate these items from other types of waste and recycle them  
responsibly to promote the sustainable reuse of material resources.  
1
Household users should contact either the retailer where they purchased this product, or their local  
government office, for details of where and how they can take these items for environmentally safe recycling.  
Business users should contact their supplier and check the terms and conditions of the purchase contract.  
This product and its electronic accessories should not be mixed with other commercial wastes for disposal.  
Correct disposal of batteries in this product  
(Applicable in the European Union and other European countries with separate battery return systems.)  
This marking on the battery, manual or packaging indicates that the batteries in this product should not  
be disposed of with other household waste at the end of their working life. Where marked, the chemical  
symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference  
levels in EC Directive 2006/66. If batteries are not properly disposed of, these substances can cause harm  
to human health or the environment.  
To protect natural resources and to promote material reuse, please separate batteries from other types of  
waste and recycle them through your local, free battery return system.  
4 – COAXIAL REMOTE CONTROLLER  
 
Important Safety Instructions  
1. Read these instructions.  
a
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not use this apparatus near water.  
6. Clean only with dry cloth.  
7. Do not block any ventilation openings. Install in accordance with the  
manufacturer’s instructions.  
g
8. Do not install near any heat sources such as radiators, heat registers, or other  
apparatus (including amplifiers) that produce heat.  
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A  
polarized plug has two blades with one wider than the other. A grounding type  
plug has two blades and a third grounding prong. The wide blade or the third  
prong is provided for your safety. If the provided plug does not fit into your outlet,  
consult an electrician for replacement of the obsolete outlet.  
h
10. Protect the power cord from being walked on or pinched particularly at plugs,  
convenience receptacles, and the point where they exit from the apparatus.  
11. Only use attachments/accessories specified by the  
manufacturer.  
12. Use only with cart, stand, tripod, bracket, or table  
specified by the manufacturer, or sold with the apparatus.  
nt)  
ms)  
13. Unplug this apparatus when a card is used. Use caution  
when moving the cart/ apparatus combination to avoid  
injury from tip-over.  
14. Refer all servicing to qualified service personnel. Servicing is required when the  
apparatus has been damaged in any way, such as powersupply cord or plug is  
damaged, liquid has been spilled or objects have fallen into the apparatus, the  
apparatus has been exposed to rain or moisture, does not operate normally, or  
has been dropped.  
ing.  
act.  
osal.  
ms.)  
rm  
f
English 5  
 
Contents  
I
Introduction  
Introduction  
6
7
T
a
Part names and functions  
Installation  
Checking Installation Environment  
11  
11  
Installation precautions  
Connection & Control  
To Control the camera coaxial communications  
12  
13  
To control the camera using RS-485 device  
via coaxial communications  
To control the camera using RS-232 device  
via coaxial communications  
14  
15  
To control the camera using RS-485 signal output  
To control the camera using RS-485 signal  
output via RS-232 communications  
16  
17  
Switch Setting Table  
Specifications  
Specifications  
20  
21  
Dimensions  
6 – COAXIAL REMOTE CONTROLLER  
 
Introduction  
INTRODUCTION  
This remote controller can control A1 series cameras through A1 coaxial connection,  
and can control COAXITRON supporting cameras through COAXITRON communication.  
Features  
Long-distance remote control  
Through RS-485 communication, remote control is possible up to 1.2  
kilometers.  
Easy Control  
Easy and simple 5-way keys for controlling the camera.  
List of controllable models  
Capable of controlling A1 series camera products.  
You can control cameras supporting COAXITRON.  
What’s Included  
COAXIAL REMOTE  
CONTROLLER  
User Manual  
SPC-300  
<Controller>  
<User Guide>  
English 7  
 
Introduction  
PART NAMES AND FUNCTIONS  
Front Panel  
n
o
p
POWER  
POWER  
STATUS  
s
t
ADDRESS  
(X)100  
OFF  
CABLE  
ON  
(X)10  
(X)1  
COMPENSATION  
q
r
S
L
TERMINATION  
PROTOCOL  
REMOTE CONTROLLER SPC-300  
STATUS LED  
- Displays the status of the current operation.  
POWER LED  
- Switch to select the power source from DC 12 V or 4 AA batteries.  
POWER Switch  
- If you slide it to ON, the controller turns on.  
CABLE COMPENSATION Switch  
- For long distance coaxial communications, you can use this switch for amplifying  
the control signal.  
RS-485 TERMINATION & PROTOCOL Setting Switch  
- You can select to set the RS-485 termination (left 2-pin piano switch).  
- To set the RS-485 termination (left 2-pin piano switch), turn the switch ON.  
N
ON  
ON  
1
2
1
2
3
4
5
6
7
8
TERMINATION  
PROTOCOL  
8 – COAXIAL REMOTE CONTROLLER  
 
Introduction  
-
For multi-protocol settings, you can set the protocol (right 8-pin piano switch),  
baud rate, and communication mode of COAXIAL/COAXITRON/RS-485/RS-232.  
ON  
ON  
1
2
1
2
3
4
5
6
7
8
TERMINATION  
PROTOCOL  
- Use pin 1,2,3 of the Protocol setting switch to select a protocol.  
- The protocol switch pin 4 sets the protocol to COAXIAL or COAXITRON.  
- Use pin 5,6 of the Protocol setting switch to select a baud rate.  
s
t
- The protocol switch pin 7 sets the protocol to COAXIAL (BNC communication)  
or RS-485 output.  
- Use pin 8 of the Protocol setting switch to select RS-232 input.  
Address Switch  
-
For RS-232 / RS-485 communications, you can use this switch to set the address.  
ADDRESS  
(X)100  
(X)10  
(X)1  
- Set the address by using three switches shown above.  
- From the left, the number is hundreds, tens and ones place, respectively.  
The effective range of valid address is between 0 and 255 (1~255 for multi-  
protocol).  
g
Menu Navigation Key  
Use this to navigate through the menus.  
ƒ
For further details on ON/OFF setting of each switch for the applicable configuration,  
refer to SPC-300 Connection and Control section.  
NOTE  
English 9  
 
Introduction  
PART NAMES AND FUNCTIONS  
Rear Panel  
- AA BATTERY  
You can use 4 AA-sized batteries for the power.  
- The average operation time is 20 hours based on the alkaline battery.  
(If the battery is discharged, it can cause a distortion of the video signal, or  
electric interference.)  
ƒ
Remove the battery if you do not use the controller for a longer period. Otherwise, it  
may cause damage to the controller from a leak of the battery solution.  
NOTE  
ƒ
ƒ
ƒ
Take caution not to change the specified polarity.  
Do not use a new battery with an old one.  
For storing used batteries, keep out of reach of children. Wasted batteries are to be  
collected separately.  
10 – COAXIAL REMOTE CONTROLLER  
 
Introduction  
Top  
R E M O T E C O N T R O L L E R S C P - 3 0 0  
P R O T O C O L  
T E R M I N A T I O N  
2
3 1  
4
5
6
7
2 8  
1
O N  
O N  
S
L
C O M P E N S A T I O N  
C A B L E  
O F F  
( X ) 1  
( X ) 1 0  
( X ) 1 0 0  
A D D R E S S  
O N  
O W E R  
S T A T U S  
P O W E R  
RS-485  
DC 12V  
VIDEO  
RS-232C  
TX  
RX  
T IN  
n
o
p
q
r
USB Port  
- This terminal is used for updating the product’s firmware.  
RS-232 Port (9-pin D SUB)  
- Used to control remotely using RS-232 communication.  
RS-485 Port (4-pin)  
- Used to control remotely using RS-485 communication.  
VIDEO IN/OUT Connector (BNC)  
- VIDEO IN receives coaxial communication from cameras, and VIDEO OUT  
outputs the video signal.  
DC12V Power Connector (2-PIN)  
- Used for connecting DC12V power source.  
English 11  
 
Installation  
CHECKING INSTALLATION ENVIRONMENT  
T
K
Please check the following instructions before installation for your safety.  
The way of connecting the main product with external devices (COAXIAL BNC)  
is very important to build up a proper system.  
Do not disassemble the unit; doing so could expose you to dangerous high  
voltage points.  
INSTALLATION PRECAUTIONS  
Make sure you turn off the product before installation.  
Do not put a strong force on or shake the product; otherwise it may cause  
malfunction.  
1
2
Keep the product away from areas of strong magnetic field or electric  
interference, or wireless devices such as radio or TV set.  
Keep clean the installation place during and after the installation.  
An abnormal smells from the product is a sign of abnormal condition, which  
may cause fire or electric shock. In this case, disconnect the product from  
the main power immediately and contact the retailer for technical help from  
authorized servicing.  
3
4
Keep the product away from a wet floor, do not use an unearthed power  
extension cable, worn-out power cord, neither forget earth-grounding.  
Use a dry cloth only to dirt off the product. If the product is badly dirty, apply  
neutral detergent on a cloth that is used to dirt off, and wipe it out with a dry  
cloth.  
Do not use volatile substances such as alcohol, benzene or thinner as these  
may damage the finish.  
12 – COAXIAL REMOTE CONTROLLER  
 
Connection & Control  
TO CONTROL THE CAMERA USING CONTROL MENU  
KEYS AND COAXIAL / COAXITRON OUTPUT  
R E M O T E C O N T R O L L E R S C P - 3 0 0  
P R O T O C O L  
T E R M I N A T I O N  
2
1 3  
4
5
6
7
2
8
1
O N  
O N  
S
L
C O M P E N S A T I O N  
C A B L E  
O F F  
X (  
) 1  
( X ) 1 0  
( X ) 1 0 0  
A D D R E S S  
O N  
W E R  
S T A T U S  
P O W E R  
1. Connect the product to DC 12V power source or insert 4 AA-sized  
batteries into the battery compartment.  
(Power can be supplied via USB cable connection.)  
2. Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera directly.  
The A1 camera and SPC-300 should be directly connected to the VIDEO IN.  
3. Connect VIDEO OUT of the main unit to a monitor’s video input terminal.  
4. You can control camera menu after setting the switch as shown below:  
PIN 4  
ON  
OFF  
Output Selection  
COAXITRON  
A1 COAXIAL  
ON  
1
2
3
4
5
6
7
8
PROTOCOL  
PIN 7  
ON  
OFF  
Output Selection  
COAXIAL OUT  
RS-485 OUT  
ON  
1
2
3
4
5
6
7
8
PROTOCOL  
Select the coaxial output by using the protocol switch pin 7.  
The pin 7 coaxial / RS-485 has the output priority.  
To select from COAXIAL or COAXITRON, use the pin 4.  
You can use the menu as following :  
Press and hold [ENTER]: Moves to the main menu screen.  
Press [ENTER] briefly: Used to confirm the current settings.  
Four Direction Keys: Used to move the cursor up/down or left/right.  
ƒ
ƒ
No address setting is required for connecting COAXIAL / COAXITRON camera and SCP-300.  
If not in menu control, it operates ZOOM/FOCUS function for COAXIAL output. If not in  
menu control, it operates PAN/TILT function for COAXITRON output.  
For COAXIAL control, the camera should be set to SAMSUNG-E protocol.  
When controlling COAXITRON menu while the menu is turned on, press and hold  
ENTER key to exit the menu screen.  
NOTE  
ƒ
ƒ
English 13  
 
Connection & Control  
TO CONTROL THE CAMERA USING RS-485 INPUT  
AND COAXIAL / COAXITRON OUTPUT  
T
V
R E M O T E C O N T R O L L E R S C P - 3 0 0  
P R O T O C O L  
T E R M I N A T I O N  
2
1 3  
4
5
6
7
2
8
1
O N  
O N  
S
L
C O M P E N S A T I O N  
C A B L E  
O F F  
1  
( X ) 1 0  
( X ) 1 0 0  
A D D R E S S  
O N  
P O W E R  
S T A T U S  
P O W E R  
1. Connect the product to DC 12V power source or insert 4 AA-sized  
batteries into the battery compartment.  
(Power can be supplied via USB cable connection.)  
1
2. Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera  
2
3
directly.  
The A1 camera and SPC-300 should be directly connected to the VIDEO IN.  
3. Connect VIDEO OUT of the main unit to a monitor’s video input terminal.  
4. Connect TX(+/-) of RS-485 device to RX(+/-) of the main unit.  
(For a full duplex system, connect RX(+/-) of RS-485 device to TX (+/-) of  
main unit additionally.)  
4
5
6
5. Use a combination of pin 1,2,3 of the Protocol setting switch to select a  
protocol.  
Refer to the switch configuration table. (See page 18)  
6. Using RS-485 device, you can control the camera menu.  
ƒ
ƒ
Each mentioned protocol may require updating the firmware from the website.  
NOTE  
By factory default, protocols of SAMSUNG-E, SAMSUNG-T and PELCO-D/P are  
supported.  
ƒ
ƒ
ƒ
ƒ
To support additional protocol, access the website to update the program.  
RS-232 and RS-485 communications cannot be used simultaneously.  
COAXIAL and COAXITRON cannot be used simultaneously.  
N
RS-485 input and COAXITRON control supports SAMSUNG-E and SAMSUNG-T  
protocols only, while COAXIAL control supports all protocols.  
ƒ
For COAXIAL control, the camera should be set to SAMSUNG-E protocol.  
14 – COAXIAL REMOTE CONTROLLER  
 
Connection & Control  
TO CONTROL THE CAMERA USING RS-232 DEVICE  
VIA COAXIAL COMMUNICATIONS  
R E M O T E C O N T R O L L E R S C P - 3 0 0  
P R O T O C O L  
T E R M I N A T I O N  
2
1 3  
4
5
6
7
2
8
1
O N  
O N  
S
L
C O M P E N S A T I O N  
C A B L E  
O F F  
( X ) 1  
( X ) 1 0  
( X ) 1 0 0  
A D D R E S S  
N O  
W E R  
S T A T U S  
P O W E R  
1. Connect the product to DC 12V power source or insert 4 AA-sized  
batteries into the battery compartment.  
(Power can be supplied via USB cable connection.)  
2. Set the protocol switches 7 and 8 to ON.  
3. Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera  
directly.  
For proper data communication, the unit and AI camera should be connected directly.  
(If you connect a DVR or keyboard in the middle of the main unit and AI camera,  
bidirectional communication will not be established.)  
of  
4. Connect VIDEO OUT of the main unit to a monitor’s video input terminal.  
5. Connect the RS-232 device’s cable to the RS-232 port of the main unit.  
6. Using RS-232 device, you can control the camera menu.  
The RS-232 device is the same as RS-485 regarding the protocol setting, but  
supports only the Samsung protocol.  
For proper coaxial communication, AI camera should be set to Samsung protocol.  
Refer to the switch settings. (See page 18)  
ƒ
RS-232 and RS-485 communications cannot be used for simultaneous input.  
RS-232 device control supports SAMSUNG-E protocol only.  
NOTE  
ƒ
English 15  
 
Connection & Control  
TO CONTROL THE CAMERA USING RS-485 OUTPUT  
AND CONTROL MENU KEYS  
T
O
R E M O T E C O N T R O L L E R S C P - 3 0 0  
P R O T O C O L  
T E R M I N A T I O N  
2
1 3  
4
5
6
7
2
8
1
O N  
O N  
S
L
C O M P E N S A T I O N  
C A B L E  
O F F  
X ) 1  
X ) 1 0  
( X ) 1 0 0  
A D D R E S S  
O N  
P O W E R  
S T A T U S  
P O W E R  
1. Connect the product to DC 12V power source or insert 4 AA-sized  
batteries into the battery compartment.  
(Power can be supplied via USB cable connection.)  
1
2. Connect the RX(+/-) of the unit to the RS-485 (+/-) port of the camera.  
2
3
4
3. Match the camera’s address, baud rate, and protocol to the same to  
those of the unit.  
-
For address switch, refer to the page 8.  
3. Now you can control the camera by using the menus.  
You can use the menu as following :  
5
6
Press and hold [ENTER]: Moves to the main menu screen.  
To exit the menu screen, press and hold the key again.  
Press [ENTER] briefly: Used to confirm the current settings.  
Four Direction Keys: Used to move the cursor up/down or left/right.  
Control of pan/tilt/zoom using the buttons is not supported.  
N
ƒ
RS-232 and RS-485 communications cannot be used simultaneously.  
5-direction key (control menu) only supports A1 camera’s menu control.  
NOTE  
ƒ
16 – COAXIAL REMOTE CONTROLLER  
 
Connection & Control  
TO CONTROL THE CAMERA USING RS-485 SIGNAL  
OUTPUT VIA RS-232 COMMUNICATIONS  
R E M O T E C O N T R O L L E R S C P - 3 0 0  
P R O T O C O L  
T E R M I N A T I O N  
2
1 3  
4
5
6
7
2
8
1
O N  
N  
S
L
C O M P E N S A T I O N  
C A B L E  
O F F  
X (  
) 1  
( X ) 1 0  
( X ) 1 0 0  
A D D R E S S  
N O  
W E R  
S T A T U S  
P O W E R  
1. Connect the product to DC 12V power source or insert 4 AA-sized  
batteries into the battery compartment.  
(Power can be supplied via USB cable connection.)  
2. Set the protocol switch 8 to ON.  
3. Connect the RX(+/-) of the unit to the RS-485(+/-) port of the camera.  
4. Match the camera’s address, baud rate, and protocol to the same to  
those of the unit.  
RS-232 device control supports SAMSUNG-E protocol only.  
5. Connect the RS-232 device’s cable to the RS-232 port of the main unit.  
6. Using RS-232 device, you can control the camera menu.  
ƒ
ƒ
ƒ
RS-232 and RS-485 communications cannot be used for simultaneous input.  
For the switch settings, see the switch setting table. (See page 18)  
Input of video signal is required to control RS-485.  
NOTE  
English 17  
 
Connection & Control  
SWITCH SETTING TABLE  
Use a combination of pin 1,2,3 of the Protocol setting switch to select a protocol.  
ON  
ON  
1
2
1
2
3
4
5
6
7
8
TERMINATION  
PROTOCOL  
Protocol Setting Switch  
Software  
Type  
(A, B, C, D)  
(0 :r, 1 :q)  
Protocol  
HALF/FULL  
PIN 1  
PIN 2  
PIN 3  
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
0
0
0
0
0
0
1
1
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
SAMSUNG-E  
SAMSUNG-E  
SAMSUNG-T  
SAMSUNG-T  
PELCO-D  
PELCO-D  
PELCO-P  
PANASONIC  
PANASONIC  
HONEYWELL  
HONEYWELL  
VICON  
HALF  
FULL  
ALL  
ALL  
A
SIMPLEX  
FULL  
A
SIMPLEX  
FULL  
A
A
SIMPLEX  
HALF  
A
B
FULL  
B
SIMPLEX  
FULL  
C
C
HALF  
D
VICON  
FULL  
D
AD  
SIMPLEX  
FULL  
D
AD  
D
Use pin 4, 7 and 8 of the Protocol setting switch to set the coaxial output.  
PIN 4  
ON  
Output Selection  
COAXITRON  
A1 COAXIAL  
ON  
1
2
3
4
5
6
7
8
OFF  
PROTOCOL  
PIN 7  
ON  
Output Selection  
COAXIAL OUT  
RS-485 OUT  
ON  
1
2
3
4
5
6
7
8
OFF  
PROTOCOL  
PIN 8  
ON  
RS-232 input  
RS-232 input  
RS-232 No use  
ON  
1
2
3
4
5
6
7
8
OFF  
PROTOCOL  
ƒ
Setting of the PIN 7 overrides that of PIN 4.  
NOTE  
18 – COAXIAL REMOTE CONTROLLER  
 
Connection & Control  
See the following table to set the baud rate.  
ON  
ON  
1
2
1
2
3
4
5
6
7
8
TERMINATION  
PROTOCOL  
BAUD RATE  
PIN 5  
OFF  
ON  
PIN 6  
OFF  
OFF  
ON  
38400 BPS  
19200 BPS  
9600 BPS  
4800 BPS  
OFF  
ON  
ON  
t.  
English 19  
 
Specifications  
SPECIFICATIONS  
Item  
D
Description  
COAXIAL / COAXITRON INTERFACE  
Max. 500m (with 5C-2V cable)  
D-SUB 9P  
Communication Method  
COAXIAL  
Range  
Connector Type  
Port  
1 Port  
RS-232  
4800/9600/19200/38400bps  
(Only Samsung protocol supported)  
BAUD RATE  
Connector Type  
4P Terminal Type  
1 Port  
RS-485  
Port  
BAUD RATE  
4800 / 9600 / 19200 / 38400 bps  
S/W PROGRAM UPLOAD  
USB PORT(USB2.0)  
Composite Video  
1.0Vp-p, 75ohm,  
VIDEO IN/OUT  
Cable Compensation out  
(Select:S/L)  
A) SAMSUNG-E, SAMSUNG-T, PELCO-D/P  
B) SAMSUNG-E, PANASONIC  
Multi-protocol (Supports 4 programs)  
Operating Temp.  
C) SAMSUNG-E, HONEYWELL  
D) SAMSUNG-E, VICON, AD  
-10˚C ~ +50˚C  
Less than 90%  
DC12V 10%  
150(W) X 36(H) X 102(D)  
200 g  
Environmental  
Conditions  
Humidity  
POWER  
DIMENSIONS (WxHxD)  
WEIGHT  
NET  
20 – COAXIAL REMOTE CONTROLLER  
 
Specifications  
DIMENSIONS  
Unit (mm)  
English 21  
 
SALES NETWORK  
SAMSUNG TECHWIN CO., LTD.  
Samsungtechwin R&D Center, 701, Sampyeong-dong, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea, 463-400  
TEL : +82-70-7147-8740~60, FAX : +82-31-8018-3745  
SAMSUNG TECHWIN AMERICA Inc.  
SAMSUNG TECHWIN EUROPE LTD.  
1480 Charles Willard St, Carson, CA 90746, UNITED STATES  
Tol Free : +1-877-213-1222, FAX : +1-310-632-2195  
Samsung House, 1000 Hillswood Drive, Hillswood Business Park Chertsey,  
Surrey, UNITED KINGDOM KT16 OPS  
TEL : +44-1932-45-5300, FAX : +44-1932-45-5325  
AB68-00857A  
P/NO. : Z6806-1331-01A  
 

PYLE Audio Speaker PHSP10TA User Guide
Radio Shack CD Player PLCD39 User Guide
Radio Shack Portable DVD Player 16 3314 User Guide
RCA DVD Player RTD315WR User Guide
RCA Flat Panel Television 46LA45RQ User Guide
Renesas Computer Hardware M3062PT EPBM User Guide
Roper Clothes Dryer RED4400V User Guide
Roper Refrigerator RS22AQXM User Guide
Samsung Air Conditioner AP500F User Guide
Samsung Film Camera NX1 User Guide